Please click here to apply through our internal career site Find Jobs - Elekta.
Elekta is shaping the standard of care, together with healthcare providers, by developing precision radiation medicine that brings advanced radiotherapy into routine clinical practice. Our solutions support consistent, efficient and personalized care, addressing evolving patient needs. Through adaptive radiotherapy, precision treatment delivery and integrated workflows, Elekta supports care teams across a range of clinical settings. Each year more than 2 million patients are treated using Elekta solutions across over 130 countries. Elekta is headquartered in Stockholm, Sweden, with over 4,000 employees and offices in more than 40 countries. The company is listed on Nasdaq Stockholm. For more information, visit elekta.com.
Introduction
Radiotherapy targets and surrounding anatomy can move during treatment. The Elekta Unity combines an MR scanner with a linear accelerator, permitting anatomy to be visualised during radiation delivery, and enabling correction based on live information.
This project will investigate how synthetic MR image data can be used to accelerate the development and evaluation of motion-management technologies on the Elekta Unity. The student will generate anatomically plausible motion within MR images, create realistic Unity-like cine datasets with known ground truth, and develop quantitative methods for assessing tracking accuracy. The resulting framework will provide a reusable platform for benchmarking current and future motion-tracking algorithms.
Background
A radiotherapy treatment is designed with millimeter precision to ensure that high doses of radiation can be delivered to the target, whilst avoiding critical anatomic structures. However, both the target and the surrounding anatomy may move during treatment, due to a range of physiological processes such as respiration, peristalsis, and organ drift. The Elekta Unity can visualize and respond to this motion in real-time, increasing dosimetric accuracy, and thus improving patient outcomes.
The current Automatic Position Management (APM) framework acquires an orthogonal pair of 2D cine images at a rate of 5 Hz. Each image is compared to a reference using rigid registration to estimate target motion from cine MR images. This method is challenged in cases where there is deformation of anatomy or so called “through-plane motion” i.e. anatomical motion normal to the imaging plane.
It may be possible to improve the performance of APM, i.e. by accounting for deformable motion or by modifying the imaging planes. However, it is not possible to verify these improvements without a reliable ground truth. Therefore, we propose creating a series of 3D images with anatomically plausible motion and extracting 2D images from them. This will allow algorithms to be tested on the 2D images and compared to a 3D ground truth.
Problem Statement
The project will address three linked problems:
Output
Who are we looking for?
We are looking for a master’s student in medical physics, computer science, applied mathematics, engineering physics, or a related scientific discipline.
Required profile:
Desirable experience:
Practicalities
Location: Elekta office, Stockholm
Supervisor: Ned Goodwin
Start date: Flexible
Copyright © 2026 Grabjobs Pte.Ltd. All Rights Reserved.